DATAPROCESS ST 230 Specifications

Browse online or download Specifications for Multifunctionals DATAPROCESS ST 230. DATAPROCESS ST 230 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 53
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
DATAPROCESS EUROPE S.p.A.
ST3xx ST4xx ST5xx
– PROGRAMMING MANUAL -
Pag.1
Programming Manual
Release 1.3
DATAPROCESS EUROPE S.p.A.
Viale Dell’Artigianato, 19
Binasco (MI)
Tel. 02- 900221 Fax 02- 900913
UV521UPG
Page view 0
1 2 3 4 5 6 ... 52 53

Summary of Contents

Page 1 - Programming Manual

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.1Programming ManualRelease 1.3DATAPROCESS EUROPE S.p.A.Viale Dell’Artigianato, 1

Page 2

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.10If a macro contains the /W command, which determines the number of labels whic

Page 3

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.11area of the label is maximised whilst taking into consideration the pressure o

Page 4

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.12only 2 metres with the Leptons parallel cable. The parallel cable is not a sta

Page 5

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.13(approx. 680 labels) unless the buffer is emptied because the external device

Page 6 - Test label

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.14(ASCII Code 4). It will then activate the receiving buffer and will function a

Page 7

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.1513 Printer control commandsThe programming language for the ST3XX, ST4XX and S

Page 8

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.1615 Commands with absolute priorityThe printer recognises sequences of 4 consec

Page 9

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.17Position Character Code Ascii DOS Code Ascii Windows32 32 003233 ! 33 003334 &

Page 10 - Auto calibration

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.1876 L 76 007677 M 77 007778 N 78 007879 O 79 007980 P 80 008081 Q 81 008182 R 8

Page 11 - ST3xx ST4xx ST5xx

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.19121 y 121 0121122 z 122 0122123 { 123 0123124 | 124 0124125 } 125 0125126 ~ 12

Page 12

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.21 Introduction...

Page 13

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.20each character in the n.th position the corresponding ASCII code. For this rea

Page 14

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.2117 The "/" command to programme the printerAll printer commands mus

Page 15

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.2211 Prints with FEED key(only blank label)12 Prints test label on switch-on.13

Page 16

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.23bspeed, 1 digit (0=38400, 1=19200, 2=9600, 3=4800, 4=2400, 5=1200, 6=600, 7=30

Page 17

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.2417.12 /$>PaaabbbcccppprrrThe /$>P command is used to change the sensiti

Page 18

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.25After correctly configuring the communication port (usually 9600,8N1), connect

Page 19

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.2617.13 / $>TiiihbbbyyyyffffmmmmnnnnttttppppThe /$>T command is used to s

Page 20

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.2717.16 /*Dx solo ST4xx ST5xxThis command is used to choose between single or d

Page 21

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.2817.18 /*OoThe /*O command is used to rotate the print in relation to the label

Page 22

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.296yes Vexp=2no7yes Vexp=2yesIf the characters under the barcode are present, th

Page 23

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.315.4 DLE-US-US-NAK...

Page 24

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.30EAN8Same rules as EAN13, but with 7 or 8 digits. UPCASame rules as EAN13, but

Page 25

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.31code where numerical and alphabetic characters coexist and where it is possibl

Page 26

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.3217.22 /CThe /C command is used to empty the buffer of the printer. All the fie

Page 27

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.33hhorizontal expansion factor (values: from 1 to 9);vvertical expansion factor

Page 28

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.34N Courier Bold 8 pts 37O Courier Bold 9 pts 43P Courier Bold 12 pts 56Q Courie

Page 29

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.35With H0010 and the autocalibration the label will come set with the gap to 10

Page 30

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.36Control characters (e.g. CR or CR+LF) can be used as field separators to allow

Page 31

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.37The printer waits for the variable fields from the computer and prints the lab

Page 32

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.38/E00300060/F211/I5000105H:I:S/A223/E00300080/I605HIDMY00010070000000000000Û/E0

Page 33

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.39The “d” parameter in the ST3xx series is used to activate the dispenser. If t

Page 34

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.417.28 /Jhhss...

Page 35

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.40Note: the position of the cursor is updated to the opposite corner of the segm

Page 36

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.41s3= time interval between the end of printing and the moment at which the sens

Page 37

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.42greater than the difference in signal (the noise) resulting from the optical d

Page 38

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.43Colour 0 (black) is normally used where black objects must be printed on a whi

Page 39

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.44than 8 characters it must be left justified with theremaining spaces blank.17.

Page 40

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.4517.40 /XiiipppThe /X command is used to change the “interline” value and it is

Page 41

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.4618 Return CodesThe printer can send information about its status to an externa

Page 42

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.4720 Status of the sensorsEvery time the control character ASCII ENQ (code 5) is

Page 43

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.48The control character ACK (code 6) is sent every time a print command is proce

Page 44

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.49the print of the label. Only new firmware relais.Printing the test label or co

Page 45

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.51 IntroductionThis document describes the programming commands for the ST302, S

Page 46

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.5023.1 Serial Ports ST3xx ST4xx ST5xxThe printer is equipped with a female 9 pi

Page 47

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.5123.2 Parallel Port – only for ST4xx ST5xxThis is the female 25 pin type “D” l

Page 48

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.521 READY - Common12 READY - Normally open13 READY – Normally closed24 READY - C

Page 49

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.53The switch or the photocell are connected in this way if the signal is to sync

Page 50

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.6conditions, with labels and ribbon correctly installed, a test label will be pr

Page 51

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.7H Alignment of label (offset)G Print area x and y coordinates originN Cutter p

Page 52

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.85 Operating statusON LINE is the normal function: the green led is on and the p

Page 53

DATAPROCESS EUROPE S.p.A.ST3xx ST4xx ST5xx – PROGRAMMING MANUAL - Pag.97 KeysThere are two keys on the control panel protected by a membrane:7.1 Pause